Functions > Macro Function > Function Key for the Macro Function

Function Key for the Macro Function
Press the key while the telephone in the idle state to execute a macro. If the H command (hang-up/pick-up with the hook key) is located at the beginning of a macro, the macro saved in the system is run immediately. If this is not the case, you need to first confirm you want the macro function to start.
In addition, you can read the status of the relevant macro on the LED.
 
Note: The commands for controlling LEDs are used on both levels of the keys. This makes it possible, for instance, to use the macro to switch the LED on, on the one key level, and to use the macro to switch LED off on the other key level. In this way the switching status of a different function that is enabled at the same time can be seen on the LED.
 
Proceed as follows by assigning the function key:
Notes:
The function can only be set up on a programmable function key that has an LED (not on a touch function key).
The Macro function fills both key levels. If one level has a macro assigned to it, the other level is also automatically filled with an empty macro.
Both macros can later be processed and executed independently of each other.
If you delete a macro from one key level, the macro is automatically deleted from the other key level.
For further information about the general procedures when assigning function keys, see Function Keys.
Additional settings for this function key are described in the following.
 
 
Account 
Select the account
 
Macro 
Enter the macro
Up to 100 characters for a maximum of 10 keys, up to 40 characters for additional keys
The following commands:
Z [number sequence]:
Number sequence selection including * and #
W [digits 1-5]:
Waiting time/pause time of 1-5 seconds
H
Hang-up/pick-up with the hook key
C
Wait for a connection
Lo
The LED next to the function key switches off
Lr
The LED next to the function key switches on (red)
Ly
The LED next to the function key switches on (yellow)
Lg
The LED next to the function key switches on (green)
Notes:
If you want to configure a programming function on the PBX as a macro, enter a pause between the password and the programming code sequence.
Pauses cannot be entered at the beginning of a macro.
The maximum pause time is 5 seconds. This restriction does not apply for the C command (waiting for a connection).
The commands for controlling LEDs are used on both levels of the keys. This makes it possible, for instance, to use the macro to switch the LED on, on the one key level, and to use the macro to switch LED off on the other key level. In this way the switching status of a different function that is enabled at the same time can be seen on the LED.
 

COMfortel 1400 IP/2600 IP/3600 IP - Firmware V2.8 - Advanced Information V09 03/2024