Event type
Proceed as follows:
Using the Configuration Manager (Périphériques > URL d’action page)
*You can find further information about the structure of an Action URL, the switching of relays, the triggering of an alarm etc. in the Auerswald DokuWiki.
Nouveau
Adds a new Action URL. You must then make the settings for this new Action URL.
Supprimer
Deletes the entries that are marked in the list.
Alarme
In the first list feld, select one of the existing alarms, select the alarm type in the second list field and click .
If you do not want to use any of the existing alarms, select Nouvelle alarme in the list field ( cancels the operation). Enter the phone number of the alarm and a freely selectable name. In the list field Type d’alarme, select the alarm type. Click Ok.
*Note: You can successively select all three alarm types for one Action URL.
Numéro de téléphone
This (exchange line access number) is an internal number. You can select any of the numbers in the internal supply of phone numbers. This number can be called directly by an internal subscriber to initiate an alarm. (Entry with Nouveau)
*Note: Double allocation of a number is not possible.
*Note: Using numbers with few digits (two or three-digit numbers) inevitably restricts the possible supply of numbers requiring more digits. For example, if the number 12 is assigned, the numbers 120-129 and 1200-1299 will no longer be available.
*Note: The default exchange line access number on the PBX is 0 in the factory settings. However, this can be changed. Note that changing the exchange line access number restricts the dial plan.
Nom
Freely selectable name. This name is used to identify the alarm within the PBX.
Type d’alarme
You can select all alarm types for one alarm:
Démarrage alarme
The Action URL will be assigned to the alarm type Démarrage alarme. When an alarm is triggered, the Action URL is sent.
*Note: If an alarm delay time was entered, the alarm call via the Action URL starts after the alarm delay time.
Alarm acknowledged
The Action URL will be assigned to the alarm type Alarme confirmée. As soon as an alarm subscriber (configured under Devices > Alarms > Configure > Alarm subscriber (destination number)) acknowlegded the alarm, the Action URL is sent
*Note: A device from another manufacturer that is not recognized by the PBX, cannot acknowlegde an alarm call by entering the DTMF digit 0.
Expiration alarme
The Action URL will be assigned to the alarm type Expiration alarme. If none of the alarm subscribers acknowledges the alarm, the alarm call ends after the set alarm loops and the Action URL is sent.
Link to page Périphériques > Alarmes
Delets the alarm or opens the configuration of the alarm.