2TSM Module
Proceed as follows:
•Using the Configuration Manager (page Devices > Device wizard > Configure)
After adding a COMmander 2TSM (R) module and the connected devices (for example, FTZ door terminals, loudspeaker system), the PBX provides functions like door functions and loudspeaker announcement.
With the module basic configuration described here, two door terminals, one announcement output, seven relays and four switch inputs are created as devices in the configuration of the PBX. The door terminals and the announcement output are allocated each an internal number where it can be called. The relays 1 to 3 are assigned to the first door terminal, the relays 4 to 6 are assigned to the second door terminal. The switch inputs 1 to 4 are assigned all to the first door terminal. Door calls can be created for the switch inputs by selecting call destinations.
Door terminal 1, Door terminal 2, Announcement output
Phone Number
This (exchange line access number) is an internal number. You can select any of the numbers in the internal supply of phone numbers. This number can be called directly by an internal subscriber.
Door terminal: When put together with the numbers of the door bell buttons, this creates 3 to 4-digit phone numbers.
*Note: Double allocation of a number is not possible.
*Note: Using numbers with few digits (two or three-digit numbers) inevitably restricts the possible supply of numbers requiring more digits. For example, if the number 12 is assigned, the numbers 120-129 and 1200-1299 will no longer be available.
*Note: The default exchange line access number on the PBX is 0 in the factory settings. However, this can be changed. Note that changing the exchange line access number restricts the dial plan.
Relay X, Switch input X
Name
Enter the names of the relays and switch inputs.
Destination number
Select or enter the required call destination (external number, short-code number, internal number of the individual phone, internal phone number of the group).
*Note: To create further configurations for a door terminal, open the page Devices > Door terminals. The configuration is described here Door Functions.
*Note: To create further configurations for the announcement output, open the page Devices > Announcement outputs. The configuration is described here Loudspeaker Announcement.
*Note: To create further configurations for the relays, open the page Devices > Relays (actuators). The configuration is described here Relays (Actuators).
*Note: For using one or more switch inputs with alarm functions, open the page Devices > Alarms. The configuration is described here Alarm.
*Note: To change the settings of the configured COMmander 2TSM (R) module, click Devices > Device wizard on Configure.
*Note: To reset the COMmander 2TSM (R) module to the default settings of the device template, on page Hardware > Selection of modules, select the option not in use and then again 2TSM module. Subsequently, open the page Devices > Device wizard and configure the COMmander 2TSM (R) module again.