•Relay/actuator (optional, see Technical Data in the Instructions)
•Created device (e.g. door terminal, IP switch relay) whose part the relay is
A relay is assigned to the alarm with the operating mode Alarme, which is used to enable e.g. a siren when the alarm has been triggered.
Select an existing relay in the list field and confirm with .
If you do not want to use any of the existing relays, select Nouveau relaisIn the list field (cancels the operation). Assign a freely selectable relay name.Ajouter à: Select the device in the list field as whose component the relay is to be created. Confirm withOk.
Note: The relay remains part of this other device (e. g. door terminal, IP switch relay) in the configuration of the PBX, but takes over the selected alarm function for the alarm.
Deletes the relay or opens the configuration of the relay.
Entrée
Requirements:
•Switch input (optional, see Technical Data in the Instructions)
•Created device (e.g. a door terminal) whose part the switch input is (e.g. a still free door bell button)
A switch input that can be used to trigger the alarm, is assigned to the alarm.
In the list field, select one of the existing switch inputs and click .
If you do not want to use any of the existing switch inputs, select the following in the list field Nouvelle entrée de signal. cancels the operation. Enter a freely selectable name for the switch input and select the device as whose part the switch input is to be created in the Ajouter à list field.
Enter a value under Séquence DTMF (for analogue door terminals) or Invite SIP (for VoIP door terminals). To detect that the alarm has been triggered, e.g. because a door bell button has been pressed, the PBX needs to know which DTMF sequence or which SIP invite the connected device sends in this case (see manual and settings of the device in question). The DTMF sequence or the SIP invite usually is the phone number assigned to the door bell button within the door terminal.
Click Ok.
Note: The switch input remains part of this other device (e.g. door terminal) in the configuration of the PBX, but takes over the selected alarm function for the alarm.
Deletes the switch input or opens the configuration of the switch input.