Buch1 > Using the Configuration Manager > Devices > Alarms > Management of the Alarms
Management of the Alarms
Proceed as follows:
Using the Configuration Manager (page Devices > Alarms)
Phone number
This is an internal number. You can select any of the numbers in the internal supply of phone numbers. This number can be called directly by an internal subscriber to initiate an alarm. (Select  New to enter.)
* Note: A number cannot be allocated twice.
* Note: Using numbers with few digits (two- or three-digit numbers) inevitably restricts the possible supply of numbers that require more digits. For example, if the phone number 12 is assigned, the phone numbers 120 to 129 and 1200 to 1299 are no longer available.
* Note: The default exchange line access number on the PBX is 0 in the factory settings. However, this can be changed. Note that changing the exchange line access number restricts the phone numbering plan.
Name
Freely selectable name. This name is used to identify the alarm within the PBX.
Enable alarm
off
The alarm input is disabled. It is not possible to initiate an alarm.
once
The alarm can be initiated only once. Subsequently, the alarm input will be disabled and will have to be enabled once again.
always
After an alarm is triggered off, the alarm input continues to be enabled. A further alarm can be triggered off.
Configure
Opens the configuration of the alarm.
 New
Adds a new alarm. You must then make the settings for this new alarm.
 Delete
Deletes the entries marked in the list.