Buch1 > Functions, Uses, Concepts > Remote Configuration and Alternative Connection Options > Configuring the PBX Remotely with (Auerswald) Remote Access Server via the Internet
Configuring the PBX Remotely with (Auerswald) Remote Access Server via the Internet
Requirements:
PBX with existing connection to the Internet (DSL)
In the PBX configured ARA PIN and remote switching number and also enabled dealer access over the Internet
-Using the Configuration Manager (page Administration > Remote configuration)
Computer with existing connection to the Internet (DSL)
DTMF-capable phone or DTMF dialler
Access data for registration at protected Auerswald services
Knowledge of the serial number of the PBX
Knowledge of user name and password for the Configuration Manager


1.Start a browser.
3.Enter the required data in the User name/Customer number and Password/PIN input fields, and click Login.
The user interface of the (Auerswald) Remote Access Server opens.
4.Register the PBX if this has not been done yet.
5.Call the remote switching number.
The PBX automatically accepts the call. You will hear the external confirmation tone (1 second.
6.Dial with DTMF ##8 ARA PIN *91#.
You will hear the external confirmation tone (1 second).
In the user interface of the (Auerswald) Remote Access Server within a few seconds the connection symbol appears in the line of the called and released PBX.
7.Click .
The login window of the Configuration Manager opens.
8.Log in to the Configuration Manager.
9.Make the desired changes.
10.Log out from the Configuration Manager.
11.Click in the user interface of the (Auerswald) Remote Access Server.