Management Configuration
Proceed as follows:
Using the Configuration Manager
Automatic configuration switching
Requirements:
Minimum of two configured configurations and configured switching times
Current PBX time
Time-controlled configurations are toggled according to the PBX internal clock.
*Note: If automatic configuration switchover is enabled, the configuration enabled under Time control > Switching times for the current time becomes active. If a different configuration is then switched manually, this remains active until the next switching time.
Controllable with system relay: Aut.Konfig.um. (900)
Requirements:
Automatic configuration switchover is enabled
Automatic configuration switchover is controllable via phone.
Configuration name
Freely selectable name. This name is used to identify the configuration within the PBX.
Identification number
Automatically issued number. Is used for manual switching of a configuration by a programming sequence.
*Note: All previously assigned identification numbers can be viewed sorted by number, name or type under Overviews > Identification number table.
Activate
The selected configuration is switched on.
*Note: To switch off a configuration, switch on a different configuration.
New
Adds a new configuration to the list. The settings made for the existing configuration are copied. You must then make the individual settings for the configuration.
Delete
Deletes the entries marked in the list.
Copy
Configuration settings are copied from one configuration into other, selected configurations.