VoIP Door Terminal
Proceed as follows:
•Using the Configuration Manager (Devices > Relays (actuators) > Configure)
CONFIGURATION OF THE RELAY
Select the relay.
PBX is decisive (primary)
The available relays on an IP switch relay can also be toggled without affecting the PBX. In some situations, e.g. if the PBX is switched off at the switching point, the PBX cannot identify the state of the relay.
The PBX restores the relay to the last state it was able to identify after it is rebooted.
Off control
Requirement:
•the relay must have been set up
The PBX will switch off relays with the operating modes Light, Door opener, Alarm and PC relay after the specified switching duration.
Note: When switched off, the hold time of the relay will be used. The PBX does not actively switch off the relay.
Note: As a a pre-requisite, off control must be supported by the relay (for some relays, e. g. the a/b Switching Modules, switching off cannot be controlled).
Switching duration
Specifies after how many seconds the PBX will switch off the relay. Possible entries: 0 to 6000 (0 only for manual relays).
Note: The switching duration is used for relays with the operating modes Light, Door opener, Alarm, PC relay and Manual relay.
Note: To enable the PBX to switch off the relay after the specified switching duration, off control must be supported by the relay and be switched on (for some relays, e. g. the a/b Switching Modules, switching off cannot be controlled). Alternatively, the hold time of the relay can be used.
Hold time
If switching off is not to be controlled by the PBx (for some relays, e.g. the a/b Switching Modules, switching off cannot be controlled), the hold time of the relay can be used instead of the switching duration. This will only make sense if the hold time of the relay is sufficiently long, for example for a door opener.
The PBX needs to know how long the relay will be held in order to signalise holding of the relay on the system phones (see the manual of the device in question).
Requirement:
•the relay must have been set up
•Off control switched on for the relay
Enter the hold time of the relay in milliseconds. Possible entries: 10 to 10000.
Relay can be triggered by Action URL
Provided that the access authorisation to Action URLs is granted system-wide or for a subscriber, the individual manual relay can be triggered by Action URLs.