NET Module
Proceed as follows:
Using the Configuration Manager (page Administration > IP Configuration)
Requirements:
Slot assigned with NET module (page Hardware > Selection of modules)
Receive the IP address automatically (DHCP client)
* Note: In the factory settings, DHCP is enabled.
The PBX receives its IP address automatically from the DHCP server.
Assigning IP address manually
Requirements:
Disabled DHCP client
IP address
Enter the IPv4 address in the range 0 to 255 (example: 192.168.0.240).
Apply immediately
The IPv4 address is immediately applied and the PBX is routed to the new IPv4 address. After the rerouting, you need to log in again.
Apply at restart
The IPv4 address is not applied until the next time the PBX is restarted.
Subnet mask
Enter the IPv4 address of the subnet mask in the range 0 to 255 (example: 255.255.255.0).
IPv6 Configuration
Opens the IPv6 configuration.
IPv6 mode
If IPv6 is switched on, an IP address complying with version 6 of the Internet protocol can be assigned to the PBX. Thanks to the greater length of IPv6 addresses (eight blocks with four digits each, example: 3001:00FF:ABC0:0EAC:0001:0000:0000:000F), IPv6 offers a greater number of available IP addresses than version 4 of the Internet protocol (IPv4).
disabled
Switches the use of IPv6 addresses off.
SLAAC
Automatically assigns an IPv6 address to the PBX.
static
Assigns a user-defined IPv6 address to the PBX.
IPv6 settings
Requirements:
IPv6 status IPv6 static selected
IPv6 address
Enter the IPv6 address of the PBX.
Prefix length
Enter the prefix length in the range 1 to 128. The prefix specifies to which subnet the IPv6 address belongs.
IPv6 Gateway
Enter the IPv6 gateway. Possible entries: Digits, characters and :.