Configuring Subscribers
Requirements:
•Telephone numbering plan - name and internal number for every analogue telephone
Configuration location:
•The PBX system used as the a/b gateway
−Subscriber (scr.) > Phone numbers
Components to be configured:
•One subscriber for every analogue telephone, with name and internal number from the telephone numbering plan:
−New > Settings under Add subscriber > Save
Make the following settings for the subscriber:
•Configure
−Module/Port: Module/port to which the telephone is connected
−Exchange line settings > Exchange line authorisation: International
−Exchange line settings > Preferred exchange line: Automatic occupation
−Authorisations > Transfer of external calls to external: on
−Settings > Exchange line request: Direct exchange line phone
−Settings > Transmission of the display name: on
Note: Properties such as the exchange line authorisation for the analogue telephone must be set via the user of the COMtrexx, not via the subscriber.