Help > Functions and applications > a/b-Gateways > Analogue terminal adapter (ATA)
Analogue terminal adapter (ATA)
Analogue phones, fax machines or door terminals can be connected to a COMtrexx via analogue terminal adapters (hereinafter referred to as ATA).
Auerswald recommends using the following ATA for up to 2 or 4 analogue devices:
•2 analogue devices: 2 port ATA FTA5102E2
•4 analogue devices: 4 port ATA G504
*Note: Alternative for COMtrexx Business and COMtrexx Flex: By upgrading with a 4FXS module, there are now four internal ports for analogue devices (telephones, fax machines, door stations, announcement outputs) available.
Supported Functions 
The following functions can be used in the normal way on the analogue telephones connected via the ATA.
•Incoming call with phone number and name display
In an external call, the name is only displayed if the phone number has been entered as a contact in the COMtrexx.
•Outgoing call
•Transfer with an announcement
•Splitting a call

Telephones connected to the COMtrexx can be used in the normal way to perform the following functions, even when used together with the analogue telephones.
•Incoming calls from analogue telephones with phone numbers and name display
•Outgoing calls to analogue telephones
•BLF status of the analogue telephones (free, call, busy)
Unsupported Functions 
The following functions cannot be used:
•Transfer without announcement (blind transfer)
•Three-way call
Setup in COMtrexx
The following components must be set up in COMtrexx.
•User for each analogue phone or fax
•Phone for any analogue phone or fax
•External device VoIP door terminal for any analogue door terminal

Configuring Users 
Components to be configured:
•One user for each analogue phone with name and internal number:
−User > Phone numbers > New > Settings > Save
•Preferences:
−Phone number : Internal number, freely selectable from the numbers in the internal supply of phone numbers.
−Name : freely selectable name

Configuring Telephones 
Requirements:
•Configured users

Components to be configured:
•One telephone for every analogue telephone:
−Telephones > Assignment > New > settings under Adding a telephone > Save
•Preferences:
−Name : freely selectable name
−Type: SIP soft client
−Manufacturer: Another manufacturer
*Important: Do not use the name Auerswald.
−User: The user configured for the telephone

Telephone data required for further use:
•SIP user name
•Password
−Telephones > Assignment > > Password

Door terminal setup 
Requirements:
•The IP address of the ATA is known (planned static IP address or basic configuration of the ATA already done))

Components to be configured:
•Import new device template:
−External Devices > Device wizard > Import > Online configuration > Universal SIP-Türmodul > Import > Close
•External device VoIP door terminal for any analogue door terminal:
−External Devices > Device wizard > New > Settings > Save
•Preferences:
−Name : freely selectable name
−Device template: Universal SIP-Türmodul
−Module: VoIP
•Additional settings under Device template door terminal
−Phone number : Internal number, freely selectable from the numbers in the internal supply of phone numbers.
−SIP password: Freely selectable password.
−IP address, Port, User name, Password: No entry.
−Name : freely selectable name
−Destination number: Select or enter the desired call destination (external/internal number).
−SIP invite: Enter the phone number that is assigned to the bell button within the door terminal (e.g. 31 or 32 in the delivery state for Auerswald door stations)

Door terminal data required for further use:
•Phone number
•SIP password

Setup on 2 port ATA FTA5102E2
To begin setting up the ATA, a basic configuration and optionally a firmware update must be performed. The basic configuration provides the most important settings for operation of the COMtrexx.
Two variants are possible:
•Automatically via Internet (recommended)
•Manually
Basic configuration and firmware update automatically via Internet (recommended) 
Requirements:
•ATA is in factory default state
•Existing network with
−COMtrexx
−DHCP server
−Internet access
Procedure:
1.Switch on the ATA (plug-in power supply) and connect the ATA to the network (WAN port).
*Please observe the instructions/safety information included with the ATA.
The ATA starts.
The firmware is updated and the basic configuration is loaded automatically.
*Important: This process takes about 10 minutes in total. Do not disconnect the ATA from the network or power supply.

2.Enter the IP address assigned by the DHCP server for the ATA in the address field of the browser.
*Note: The IP address can be determined. e,g. using an IP scanner.

3.Log in.
−User name: admin
−Password: admin
−Log in

4.If necessary, change the language of the web interface.
−Administration > Management > Administrator settings > Language
−Save & Apply

5.Set a new administrator password.
−Administration > Management > Administrator settings > Password Reset
−New password
−Confirm Password
−Save & Apply

6.Adjust the network settings if necessary.
−Network > WAN
−Save & Apply



Basic configuration and firmware update manually 
Requirements:
•ATA is in factory default state
•Firmware file stored on a storage device (computer)
*You can download the firmware file here: Download firmware file ATA FTA5102E2.

•Configuration file stored on a data storage device (computer) with the basic configuration
*You can download the configuration file here: Download configuration file ATA FTA5102E2.

•Existing network with
−COMtrexx
−DHCP server

Procedure:
1.Switch on the ATA (plug-in power supply) and connect the ATA to the network (WAN port).
*Please observe the instructions/safety information included with the ATA.
The ATA starts.
*Important: Do not disconnect the ATA from the network or power supply.

2.Enter the IP address assigned by the DHCP server for the ATA in the address field of the browser.
*Note: The IP address can be determined. e,g. using an IP scanner.

3.Log in.
−User name: admin
−Password: admin
−Log in

4.Check the firmware version.
−Status > Basic > Product Information > Firmware Version

5.Firmware version lower than V3.32: Start a firmware update.
−Administration > Firmware Upgrade > Browse> Select file from disk >Upgrade
The firmware is updated and the ATA restarts.
*Important: Do not disconnect the ATA from the network or power supply.

6.Log in.
−User name: admin
−Password: admin
−Log in

7.If necessary, change the language of the web interface.
−Administration > Management > Administrator Settings > Language
−Save & Apply

8.Set a new administrator password.
−Administration > Management > Administrator settings > Password Reset
−New password
−Confirm Password
−Save & Apply

9.Set the time zone for your location.
−Administration > Management > Time/Date Setting > NTP Settings > Time zone
−Save & Apply

10.Adjust the network settings if necessary.
−Network > WAN
−Save & Apply

11.Save the configuration file with the basic configuration.
−Administration > Management > Save Config File > Browse> Select file from disk >Upload
The basic configuration is saved.
−Click on the link shown.

12.Perform a reboot.
−Restart(Button top right)
The ATA restarts.
*Important: Do not disconnect the ATA from the network or power supply.

13.Log in.
−User name: admin
−Password: admin
−Log in



Setting up ports: 
Requirements:
•Current firmware version and basic configuration
•Users, phones and optional door terminals set up in the COMtrexx
•Values ​​known from COMtrexx for analogue phones/fax machines
−SIP user name
−Password
−Telephones > Assignment > > Password

•Values ​​known from COMtrexx for the door terminals
−Phone number
−SIP password
−External Devices > Device wizard >

•Values ​​known from COMtrexx for the internal VoIP registrar
−SIP port of the internal VoIP registrar
−VoIP registrar Ethernet interface
−Administration > VoIP > VoIP configuration > SIP
−IP addressof the internal VoIP registrar
−Network > IP configuration > LAN 1/LAN 2 > IP address


Procedure:
1.Activate the port(s).
−FXS1/FXS2 > SIP Accoun > Basic > Basic Setup
−Line Enable: Enable
−Save & Apply

2.Set up the proxy server.
−FXS1/FXS2 > SIP Accoun > Basic > Proxy and Registration
−Proxy server: Value from COMtrexx for IP address of the internal VoIP registrar
−proxy port: Value from COMtrexx for SIP port of the internal VoIP registrar
−Save & Apply

3.Set the port(s) for an analogue phone/fax machine.
−FXS1/FXS2 > SIP Accoun > Basic > Subscriber Information
−Display Name : freely selectable name
−Account: Value from COMtrexx for SIP user name
−Telephone number: Value from COMtrexx for SIP user name
−Password: Value from COMtrexx for Password
−Save & Apply

4.Set the port(s) for a door terminal.
−FXS1/FXS2 > SIP Accoun > Basic > Subscriber Information
−Display Name : freely selectable name
−Account: Value from COMtrexx for Phone number
−Telephone number: Value from COMtrexx for Phone number
−Password: Value from COMtrexx for SIP password
−Save & Apply

5.Check registration.
−Status > General > Status SIP Account > Status FXS 1 SIP Account/Status FXS 2 SIP Account
Registration status is displayed.

Setup on 4 port ATA G504
To begin setting up the ATA, a basic configuration and optionally a firmware update must be performed. The basic configuration provides the most important settings for operation of the COMtrexx.
Two variants are possible:
•Automatically via Internet (recommended)
•Manually
Basic configuration and firmware update automatically via Internet (recommended) 
Requirements:
•ATA is in factory default state
•Existing network with
−COMtrexx
−DHCP server
−Internet access
Procedure:
1.Switch on the ATA (plug-in power supply) and connect the ATA to the network (WAN port).
*Please observe the instructions/safety information included with the ATA.
The ATA starts.
The firmware is updated and the basic configuration is loaded automatically.
*Important: This process takes about 10 minutes in total. Do not disconnect the ATA from the network or power supply.

2.Enter the IP address assigned by the DHCP server for the ATA in the address field of the browser.
*Note: The IP address can be determined. e,g. using an IP scanner.

3.Log in.
−User name: admin
−Password: admin
−Log in

4.If necessary, change the language of the web interface.
−Administration > Management > Administrator settings > Language
−Save & Apply

5.Set a new administrator password.
−Administration > Management > Administrator settings > Password Reset
−New password
−Confirm Password
−Save & Apply

6.Adjust the network settings if necessary.
−Network > WAN
−Save & Apply



Basic configuration and firmware update manually 
Requirements:
•ATA is in factory default state
•Firmware file stored on a storage device (computer)
*You can download the firmware file here: Download firmware file ATA G504.

•Configuration file stored on a data storage device (computer) with the basic configuration
*You can download the configuration file here: Download configuration file ATA G504.

•Existing network with
−COMtrexx
−DHCP server

Procedure:
1.Switch on the ATA (plug-in power supply) and connect the ATA to the network (WAN port).
*Please observe the instructions/safety information included with the ATA.
The ATA starts.
*Important: Do not disconnect the ATA from the network or power supply.

2.Enter the IP address assigned by the DHCP server for the ATA in the address field of the browser.
*Note: The IP address can be determined. e,g. using an IP scanner.

3.Log in.
−User name: admin
−Password: admin
−Log in

4.Check the firmware version.
−Status > Basic > Product Information > Firmware Version

5.Firmware version lower than V4.04: Start a firmware update.
−Administration > Firmware Upgrade > Browse> Select file from disk >Upgrade
The firmware is updated and the ATA restarts.
*Important: Do not disconnect the ATA from the network or power supply.

6.Log in.
−User name: admin
−Password: admin
−Log in

7.If necessary, change the language of the web interface.
−Administration > Management > Administrator Settings > Language
−Save & Apply

8.Set a new administrator password.
−Administration > Management > Administrator settings > Password Reset
−New password
−Confirm Password
−Save & Apply

9.Set the time zone for your location.
−Administration > Management > Time/Date Setting > NTP Settings > Time zone
−Save & Apply

10.Adjust the network settings if necessary.
−Network > WAN
−Save & Apply

11.Save the configuration file with the basic configuration.
−Administration > Management > Save Config File > Browse> Select file from disk >Upload
The basic configuration is saved.
−Click on the link shown.

12.Perform a reboot.
−Restart(Button top right)
The ATA restarts.
*Important: Do not disconnect the ATA from the network or power supply.

13.Log in.
−User name: admin
−Password: admin
−Log in



Setting up ports: 
Requirements:
•Current firmware version and basic configuration
•Users, phones and optional door terminals set up in the COMtrexx
•Values ​​known from COMtrexx for analogue phones/fax machines
−SIP user name
−Password
−Telephones > Assignment > > Password

•Values ​​known from COMtrexx for the door terminals
−Phone number
−SIP password
−External Devices > Device wizard >

•Values ​​known from COMtrexx for the internal VoIP registrar
−SIP port of the internal VoIP registrar
−VoIP registrar Ethernet interface
−Administration > VoIP > VoIP configuration > SIP
−IP addressof the internal VoIP registrar
−Network > IP configuration > LAN 1/LAN 2 > IP address


Procedure:
1.Select the port to be configured.
−SIP Accoun > FXS settings
−Port: FXS 1/FXS 2/FXS 3/FXS 4
−Save & Apply

2.Activate the port(s).
−SIP Accoun > FXS settings > Basic > Basic Setup
−Port Enable: Enable
−Save & Apply

3.Set up the proxy server.
−SIP Accoun > FXS settings > Basic > Proxy and Registration
−Proxy server: Value from COMtrexx for IP address of the internal VoIP registrar
−proxy port: Value from COMtrexx for SIP port of the internal VoIP registrar
−Save & Apply

4.Set the port(s) for an analogue phone/fax machine.
−SIP Accoun > FXS settings > Basic > Subscriber Information
−Display Name : freely selectable name
−Account: Value from COMtrexx for SIP user name
−Telephone number: Value from COMtrexx for SIP user name
−Password: Value from COMtrexx for Password
−Save & Apply

5.Set the port(s) for a door terminal.
−SIP Accoun > FXS settings > Basic > Subscriber Information
−Display Name : freely selectable name
−Account: Value from COMtrexx for Phone number
−Telephone number: Value from COMtrexx for Phone number
−Password: Value from COMtrexx for SIP password
−Save & Apply

6.Check registration.
−Status > General > Status Line > Status Line 1/2/3/4
Registration status is displayed.