Event type
Proceed as follows:
•Using the Configuration Manager (Devices > Action URLs page)
*You can find further information about the structure of an Action URL, the switching of relays, the triggering of an alarm etc. in the Auerswald DokuWiki.
New
Adds a new Action URL. Then make the settings for the Action URL.
Delete
Deletes the entries marked in the list.
Alarm
In the first list feld, select one of the existing alarms, select the alarm type in the second list field and click .
If you do not want to use any of the existing alarms, select the following in the list field New alarm. cancels the operation. Enter the phone number of the alarm and a freely selectable name. In the list field Alarm type, select the alarm type. Click Ok.
*Note: You can select all three alarm types one after another for one alarm.
Phone Number
Internal number, freely selectable from the numbers in the internal phone number supply. This number can be called directly by an internal subscriber to initiate an alarm. (Entry with New)
*Note: Double allocation of a number is not possible.
*Note: Using numbers with few digits (two or three-digit numbers) inevitably restricts the possible supply of numbers requiring more digits. For example, if the number 12 is assigned, the numbers 120-129 and 1200-1299 will no longer be available.
*Note: The default exchange line access number on the PBX is 0 in the factory settings. However, this can be changed. Note that changing the exchange line access number restricts the dial plan.
Name
Freely selectable name. This name is used to identify the alarm within the PBX.
Alarm type
You can select all alarm types for one alarm:
Alarm start
The Action URL will be assigned to the alarm type Alarm start. When an alarm is triggered, the Action URL is sent.
*Note: If an alarm delay time was entered, the alarm call via the Action URL starts after the alarm delay time.
Alarm acknowledged
Alarm start: The Action URL will be assigned to this alarm type. As soon as an alarm subscriber (configured under Devices > Alarms > Configure > Alarm subscriber (destination number)) acknowledges the alarm, the action URL is sent.
*Note: A device from another manufacturer that is not recognized by the PBX, cannot acknowlegde an alarm call by entering the DTMF digit 0.
Alarm timeout
The Action URL will be assigned to the alarm type Alarm timeout. If none of the alarm subscribers acknowledges the alarm, the alarm call ends after the set alarm loops and the Action URL is sent.
Link to page Devices > Alarms
Delets the alarm or opens the configuration of the alarm.